{"product_id":"cpx-fvda-p2-ausgangsmodul","title":"CPX-FVDA-P2 Output Module ","description":"\u003cdiv class=\"productAttributes\"\u003e\n\u003cdiv class=\"productAttributesTitle\"\u003e Article attributes\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Protection class\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e depending on the terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e LABS compliance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e VDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Product weight\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 50 (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Material note\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Permissible voltage fluctuations\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e -0.7499999999999999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Permit\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e c UL us - Recognized (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Nominal operating voltage DC\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 24 (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Residual ripple\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2 Vpp within voltage range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Note regarding ambient temperature\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Note the derating curve for pneumatic connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum address volume outputs\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 6 (AD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum address volume inputs\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 6 (AD)\u003c\/td\u003e\n\u003c\/tr\u003e     \u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003eMax. cable length\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Protection (short circuit)\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e internal electronic fuse per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e PFH\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1e-09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Safety Integrity Level (SIL)\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Safe shutdown \/ SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Safety function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Safely disconnect the supply voltage to the valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Potential separation channel - channel\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Number of exits\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Switching logic outputs\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e PM switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Load capacity versus FE\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 400 (C41)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum response time to shutdown command\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e F_WD_TIME + 23 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum total current per module\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 5 (A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Voltage drop per channel\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0.6 (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":51216183001402,"sku":"1971599","price":570.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/8409\/4522\/files\/BC_Upload_2d7fb150-a781-47eb-9336-e2a9f06d1bdf.jpg?v=1748992998","url":"https:\/\/checkout.pts-group.de\/en\/products\/cpx-fvda-p2-ausgangsmodul","provider":"PTS Shop","version":"1.0","type":"link"}