{"product_id":"vpcf-6-l-8-g38-6-a4-e-ex2-proportional-durchflussregelventil","title":"VPCF-6-L-8-G38-6-A4-E-EX2 Proportional Flow Control Valve ","description":"\u003cdiv class=\"productAttributes\"\u003e\n\u003cdiv class=\"productAttributesTitle\"\u003e Article attributes\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Nominal diameter\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 6 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Protection class\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Type of operation       \u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003eelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Installation position\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e any\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum current draw\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1.2 (A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Operating medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [6:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Sealing principle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e hard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Duty cycle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Corrosion resistance class KBK\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1 - low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e LABS compliance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e VDMA24364-B1\/B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 1\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 2\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 3\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Product weight\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 856 (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Reset type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e magnetic spring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Shock resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Shock test with severity level 2 according to FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Vibration resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Transport deployment test with severity level 2 according to FN 942017-4 and EN 60068-2-6\u003c\/td\u003e     \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003eTax type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e direct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow direction\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e irreversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e symbol\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 00995603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Valve function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 3-way proportional flow control valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Material note\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Permit\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e RCM Mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Nominal operating voltage DC\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 24 (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Residual ripple\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Reverse polarity protection\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e for operating voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Display type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Short-circuit withstand capability\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Switching output\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Note on the protection class\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e in assembled state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e ATEX category gas\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e II 3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e ATEX category dust\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e II 3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Ex ambient temperature\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0°C \u0026lt;= Ta \u0026lt;= +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Ex-ignition protection type gas\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Ex nA IIC T5 X Gc\u003c\/td\u003e\n\u003c\/tr\u003e     \u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003eEx-type ignition protection for dust\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Ex tc IIIC T60°CX Dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Repeatability in ± %FS\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0.5 (YUQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Current carrying capacity per output\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 100 (MA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Hysteresis in ± %FS\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0.8 (YUQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum electrical power consumption\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 36 (W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Signal range analog output\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 4 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Signal range analog input\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 4 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Absolute accuracy in ± %FS at room temperature\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 3 (YUQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Diagnostic function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e LED indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Switch input\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Current consumption at unloaded outputs\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 150 (MA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":51216140599610,"sku":"8041713","price":1527.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/8409\/4522\/files\/BC_Upload_84445038-e980-4279-a082-b54e07c8fe79.jpg?v=1748992552","url":"https:\/\/checkout.pts-group.de\/en\/products\/vpcf-6-l-8-g38-6-a4-e-ex2-proportional-durchflussregelventil","provider":"PTS Shop","version":"1.0","type":"link"}