{"product_id":"vsva-b-b52-d-d2-1r5l-magnetventil","title":"VSVA-B-B52-D-D2-1R5L solenoid valve ","description":"\u003cdiv class=\"productAttributes\"\u003e\n\u003cdiv class=\"productAttributesTitle\"\u003e Article attributes\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Nominal diameter\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 15 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Type of operation\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Installation position\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e any\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Mounting type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e on connection plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Grid dimension\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 59 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Operating medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Sealing principle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow valve on single connection plate\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2400 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatically linked flow valve\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2800 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow valve\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 4000 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Duty cycle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Note regarding the operating\/control medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Oiled operation possible (required for continued operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Constructive design\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Piston slide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Corrosion resistance class KBK\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0 - no corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e     \u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003eLABS compliance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e VDMA24364-B1\/B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum negative test pulse for 1 signal\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 3500 (MIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum positive test pulse at 0 signal\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1000 (MIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Normalized flow rate (normalized according to DIN 1343)\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2800 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 1\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 2 according to ISO 5599-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 2\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 2 according to ISO 5599-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 3\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 2 according to ISO 5599-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 4\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 2 according to ISO 5599-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 5\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 2 according to ISO 5599-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Product weight\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 732 (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Relative humidity\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Shock resistance\u003c\/td\u003e       \u003ctd class=\"attributeValue\"\u003eShock test with severity level 2 according to FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Vibration resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Transport deployment test with severity level 2 according to FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Signal status indicator\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Tax type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e pre-controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control air supply\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow direction\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e irreversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e symbol\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 00991005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Overlay\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e positive coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Valve function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 5\/2 bistable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Material note\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Permissible voltage fluctuations\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e +\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Switching time around\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 18 (MS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Construction width\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 52 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Complies with standard\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e ISO 5599-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e       \u003ctd class=\"attributeName\"\u003eCE marking (see declaration of conformity)\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e according to EU EMC Directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Rated starting current per solenoid coil\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 165 mA to 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Rated current during current reduction\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 35 mA after 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e KC mark\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e KC-EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":51207813628218,"sku":"566995","price":236.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/8409\/4522\/files\/BC_Upload_dfb4dcc9-ff79-466c-946f-fce9a88fa34b.jpg?v=1748989419","url":"https:\/\/checkout.pts-group.de\/en\/products\/vsva-b-b52-d-d2-1r5l-magnetventil","provider":"PTS Shop","version":"1.0","type":"link"}