{"product_id":"vsva-b-d52-zh-a1-1c1-magnetventil","title":"VSVA-B-D52-ZH-A1-1C1 solenoid valve ","description":"\u003cdiv class=\"productAttributes\"\u003e\n\u003cdiv class=\"productAttributesTitle\"\u003e Article attributes\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Nominal diameter\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 9 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Type of operation\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Installation position\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e any\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Mounting type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e on connection plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e exhaust air function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e throttleable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control air connection 12\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 26 mm according to ISO 15407-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control air connection 14\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 26 mm according to ISO 15407-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Operating medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e       \u003ctd class=\"attributeName\"\u003eSealing principle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow valve on single connection plate\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1100 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatically linked flow valve\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1100 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow valve\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1400 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Duty cycle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Manual operation\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e touching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Note regarding the operating\/control medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Oiled operation possible (required for continued operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Constructive design\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Piston slide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Corrosion resistance class KBK\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0 - no corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e LABS compliance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e VDMA24364-B1\/B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Max. tightening torque valve fastening\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2 (NM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum negative test pulse for 1 signal\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 800 (MIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum positive test pulse at 0 signal\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1800 (MIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e       \u003ctd class=\"attributeName\"\u003eNormalized flow rate (normalized according to DIN 1343)\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1100 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 1\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 26 mm according to ISO 15407-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 2\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 26 mm according to ISO 15407-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 3\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 26 mm according to ISO 15407-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 4\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 26 mm according to ISO 15407-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 5\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Connection plate size 26 mm according to ISO 15407-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Product weight\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 305 (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Relative humidity\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e sound pressure level\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 85 (DBA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Shock resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Shock test with severity level 2 according to FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Vibration resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Transport deployment test with severity level 2 according to FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e       \u003ctd class=\"attributeName\"\u003eSignal status indicator\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Tax type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e pre-controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control air supply\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow direction\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e symbol\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 00992937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Overlay\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e positive coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Valve function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 5\/2 bistable-dominant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Valve size\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 26 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control interface\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e according to ISO 15218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Housing material\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Aluminum die-casting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Material note\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Permissible voltage fluctuations\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e -1.4999999999999998\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Permit\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e c UL us - Recognized (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Switching time around\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 18 (MS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":51216704176442,"sku":"547076","price":148.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/8409\/4522\/files\/BC_Upload_64f688a9-c824-4f20-9cdc-50c6697c14b9.jpg?v=1748996303","url":"https:\/\/checkout.pts-group.de\/en\/products\/vsva-b-d52-zh-a1-1c1-magnetventil","provider":"PTS Shop","version":"1.0","type":"link"}