{"product_id":"vsva-bt-m32cs1-mye-a2-1t1l-pz-magnetventil","title":"VSVA-BT-M32CS1-MYE-A2-1T1L-PZ solenoid valve","description":"\u003cdiv class=\"productAttributes\"\u003e   \u003cdiv class=\"productAttributesTitle\"\u003eArticle attributes\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Electrical connection\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Plug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Protection class\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Type of operation\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Installation position\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e any\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Mounting type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e on connection plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Operating medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Sealing principle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Duty cycle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Note regarding the operating\/control medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Oiled operation not possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Constructive design\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e plate seat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Corrosion resistance class KBK\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0 - no corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e LABS compliance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e VDMA24364-B1\/B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum negative test pulse for 1 signal\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1200 (MIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum positive test pulse at 0 signal\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2000 (MIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e       \u003ctd class=\"attributeName\"\u003eNormalized flow rate (normalized according to DIN 1343)\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 125 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 2\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 4\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Product weight\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 110 (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Shock resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Shock test with severity level 2 according to FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Vibration resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Transport deployment test with severity level 2 according to FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Tax type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e pre-controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control air supply\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow direction\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e irreversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e symbol\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 00995774\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Overlay\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e negative coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Valve function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 3\/2 closed monostable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Housing material\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e PA-enhanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e       \u003ctd class=\"attributeName\"\u003eMaterial note\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Permissible voltage fluctuations\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e +\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Construction width\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 18 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Nominal operating voltage DC\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 24 (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Switching element function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Normal flow rate venting\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 125 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":51630263370042,"sku":"8066568","price":329.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/8409\/4522\/files\/BC_Upload_3d32d429-4a6f-4ffe-8a48-cc3f3ee41fae.jpg?v=1753355554","url":"https:\/\/checkout.pts-group.de\/en\/products\/vsva-bt-m32cs1-mye-a2-1t1l-pz-magnetventil","provider":"PTS Shop","version":"1.0","type":"link"}