{"product_id":"vuvs-lt20-m52-mzd-g18-f7-magnetventil","title":"VUVS-LT20-M52-MZD-G18-F7 Solenoid Valve ","description":"\u003cdiv class=\"productAttributes\"\u003e\n\u003cdiv class=\"productAttributesTitle\"\u003e Article attributes\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Nominal diameter\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 5 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Type of operation\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Installation position\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e any\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e exhaust air function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e throttleable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Operating medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Sealing principle\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e soft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Note regarding the operating\/control medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Oiled operation possible (required for continued operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Constructive design\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e plate seat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Corrosion resistance class KBK\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2 - moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e LABS compliance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e VDMA24364-B1\/B2-L\u003c\/td\u003e     \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003eMaximum negative test pulse for 1 signal\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2700 (MIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Maximum positive test pulse at 0 signal\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 1900 (MIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Normalized flow rate (normalized according to DIN 1343)\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 500 (L2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 1\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 2\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 3\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 4\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Pneumatic connection 5\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Product weight\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 167 (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Reset type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e mechanical spring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Switching time off\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 19 (MS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Switching time\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 15 (MS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Shock resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Shock test with severity level 2 according to FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Vibration resistance\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Transport deployment test with severity level 2 according to FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e     \u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003eTax type\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e pre-controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control air supply\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control medium\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e Compressed air according to ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Flow direction\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e irreversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e symbol\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 00991024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Overlay\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e negative coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Valve function\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 5\/2 monostable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Valve size\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 21 (MM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Material note\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Permit\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e c UL us - Recognized (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control exhaust connection 84\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e b-value\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 0.31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e C-value\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e 2.1 (LSB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Control air connection 14\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"attributeName\"\u003e Connection of breathing opening\u003c\/td\u003e\n\u003ctd class=\"attributeValue\"\u003e not caught\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":51216374923578,"sku":"577495","price":74.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/8409\/4522\/files\/BC_Upload_aef87e93-efb0-4c33-bf7b-07be8259ff30.jpg?v=1748994648","url":"https:\/\/checkout.pts-group.de\/en\/products\/vuvs-lt20-m52-mzd-g18-f7-magnetventil","provider":"PTS Shop","version":"1.0","type":"link"}